All Categories
CBB61

Home /  Products /  MPP Film Capacitor /  CBB61

CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ

Introduction

Introducing, the CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Ceiling Fan 50/60HZ from the brand Xunwande. This is the perfect product for any homeowner or electrician that wants to ensure their ceiling fan runs smoothly and efficiently.

 

This capacitor is designed to help start and run the motor of your ceiling fan. By using this capacitor, you can expect your ceiling fan to run quietly and reliably. With its 2.5UF capacity, it can also handle heavy loads and high temperatures, making it ideal for any type of ceiling fan and any home environment.

 

One great feature of this capacitor is its bend cutting lug. This allows for easy installation and secure connection to your ceiling fan. The 25/70/21 dimension of this capacitor is also a standard size, so you won't have to worry about compatibility issues.

 

This capacitor is rated for 250V, which means it can handle a wide range of voltages and power fluctuations. It's also compatible with both 50Hz and 60Hz ceiling fans, providing even more flexibility and convenience.

 

If you're looking for a reliable and efficient motor running capacitor, the CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Ceiling Fan 50/60HZ is the perfect product for you. It's built to last and can withstand harsh conditions, ensuring your ceiling fan runs smoothly for years to come.

 

And with the Xunwande brand, you can have peace of mind knowing you're getting a high-quality product that's backed by a trusted and reputable company. So why wait? Upgrade your ceiling fan with the CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug from Xunwande and enjoy a quiet and reliable fan today


Products Description
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ supplier
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ manufacture
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ details
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ factory
Product Paramenters
                                            Common Dimension                                            Unit:mm

Rated Cap
        250VAC
350VAC
400VAC
450VAC
500VAC





L*W*H
L*W*H
L*W*H
L*W*H
L*W*H




1.0UF
32*12*22
32*10*20
——
37*11*22
37*12.5*22





1.2UF
32*12*22
——
32*12*22
37*11*22
37*13.5*24





1.5UF
32*12*22
——
37*11*22
37*13.5*24
——





1.8UF
32*12*22
——
——
37*15*25
——





2.0UF
32*12*22
——
37*13.5*24
37*15*25
37*17*28





2.2UF
32*12*22
——
——
37*17*28
——





2.5UF
32*12*22
37*15*25
37*15*25
37*15*25
——





2.8UF
32*12*22
——
——
37*19*30
——





3.0UF
32*12*22
37*17*28
38*17*28
37*18.5*29
47*16*33





3.2UF
——
——
——
37*19*30
——





3.5UF
37*12.5*22
——
——
38*19.5*31
——





3.8UF
——
——
——
37*19*30
——





4.0UF
37*12.5*22
37*18.5*29
37*18.5*29
47*17*31
47*19.5*33





5.0UF
37*13.5*24
——
38*19.5*31
48*22*35
47*23*35





6.0UF
37*15*25
——
——
48*22*35
47*24*37





8.0UF
37*17*28
——
48*22*35
47*27*37
58*26*38





10UF
38*19.5*31
——
——
58*26*38
——





12UF
47*17*31
——
——
59*30*42
——





15UF
47*20*33
——
——
58*32*43
——





20UF
48*35*22
——
——
68*30*45
——





Product Application
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ factory
Company Profile
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ details
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ supplier
Capacitor
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ supplier
Exhibition
CBB61 250V 2.5UF Motor Running Capacitor with Bend Cutting Lug 25/70/21 for Celling Fan 50/60HZ supplier
FAQ

1: What is the principle of explosion-proof safety film capacitor?

   The metallized electrodes adopt tiny fuses structure. If there is any failure during capacitor operation, the power supply is automatically cut off by disconnecting the micro-fuse. In this way, the failure can be prevented and self-safety protection realized.
2: What is ROHS?
    RoHS: the Restriction of the use of certain hazardous substances in electrical and electronic equipment. The regulation is a European Union(EU) ban on the use of six hazardous substances in electronic products entering Europe. in the RoHS standard, the maximum limits of six hazardous substances are: lead (Pb). mercury (Hg), hexavalent chromium(Cr6+) poly-brominated biphenyls(PBB). poly-brominated diphenyl ethers PBDE maximum allowable content of 0.1% 1000ppm cadmium (CD) is 0.01% 100ppm. This limit is the legal basis for determining whether a product complies with the RoHS directive
3: The Common Installation Methods of Fan Capacitor
   XWD ac motor capacitors are used for starting. running and adjusting speed. XWD-Capacitor
are widely applied in table tans, floor fans ceiling fans, wall fans, luxury ceiling fans, exhaust fans, extractor fans, heater, smash paper machine, turbine, dehumidifier, etc. Noted: Since the capacitor is made of plastic material, improper installation of the capacitor can cause the plastic ear to break. Therefore, the customer should pay attention to the URYU, screw, hole position to maintain vertical state during the fan capacitor installation.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

RELATED PRODUCT

We are here to support you business

Get a Quote

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000